Spacerlink - Safetylink Concrete Mounted

Product Code: SPACE001
What am I used for?

An anchor point designed for use in concrete where an extended length is required. Standard SpacerLink 250mm rod, advise length required when needed.

  • Energy absorbing eyebolt, which reduces the force on the person and the structure.
  • Stainless steel construction.
  • Multi-directional fall protection.
  • Single person anchor.
  • Rated at 15kN.
  • Complies with Australian and New Zealand Standard AS/NZS 1891.4:2025

1 Rated 15kn

Multi-Directional 360

Concrete Roof

Product Information
Spacerlink Roof Anchor

SafetyLink’s SpacerLink is designed for use in concrete where an extended length is required. The standard size of the SpacerLink rod is 250mm (advise length when needed), ask about other configurations to suit your job.

The eyebolt range starts with SafetyLink’s standard eyebolt which is designed for fall arrest, it’s long tapered stem is designed to absorb energy while arresting a fall therefore reducing the load off the structure and the person in the event of a fall.

Alternatively SafetyLink’s Abseiling Eyebolt is a fall arrest rope access anchor which uses the same tapered concept as the standard eyebolt but incorporates a shorter design enabling the eyebolt to withstand a live load without activating the bending motion that occurs when arresting a fall. Where a low profile design is more desirable a Collared Eyebolt can be used to achieve this.

Product Components
Components
Product Description Quantity
Abseil Eyebolt: 316 S/Steel with Locking Hex Nut 1
Washer with Foam backing: 70 OD 1
Spacer Insert: 316 Stainless Steel 1
Threaded Rod: M16 250mm **ADVISE LENGTH** 1
Washer: 70 OD SS 1
Nut: 16mm SS 1

STANDARD COMPLIANCE

Manufacturing Standard

This concrete anchor is compliant with AS5532:2025 and can be loaded in the directions shown in the product instruction handbook, download copy at www.safetylink.com.

Selection, Use and Maintenance Standard

To be compliant with AS/NZS1891.4:2025, when fixed with Chemical or Friction fasteners into concrete, all single fix concrete anchor shall be proof tested annually to 50% of its design load. Records of this proof test shall be kept and made available for future inspections. For multi fix concrete anchor an exemption may apply from annual proof testing if the appropriate information and documentation have been recorded at the time of installation and is available for future inspections. See AS/NZS1891.2025 Section 8 for further details.

All products must be installed in accordance with SafetyLink’s installation handbook, using only products supplied by SafetyLink Pty Ltd.

Menu